Kobayashi, Hideo; ; ; ; ; *; *
JNC TN8440 2001-005, 33 Pages, 2001/02
Four mass spectrometers are used for plutonium and uranium isotopic composition analysis in the Plutonium Fuel Center. Analytical errors of the analysis was evaluated based on routine control data obtained with measurement of reference materials. It was confirmed that the errors satisfied the International Target Values for safeguard analysis, and the random error of the analysis was improved by changing conventional method to total evaporation method.
; ; ; Ikeda, Hisashi ; Jitsukata, Shu*; *
JNC TN8410 2000-022, 55 Pages, 2000/05
Measurement of U and Pu concentrations by wavelength dispersion type X-ray fluorescence spectrometry was studied. Sample holder was installed inside of glove box and other instruments, X-ray tube, monochromator and detectors were set out side of the glove box. X-rays was irradiated to sample though Be window. Fluorescent X-rays form sample were also passing though the same Be window and detected outside. Analytical conditions were optimized as follows. Sample thickness is 8 mm, which is 3ml of sample volume by the sample holder. Voltage and eurrent for X-ray tube is 50kV and 40 mA, respectively. Measurement was done twice, 60 seconds each, and averaged X-ray intensity was used to calculate elemental concentrations. Matrix correction was necessary to measure U and Pu concentration within 10% accuracy. Detection limits were calculated to 0.4 mg/L for U and 0.7mg/L for Pu. Calibration curve was liner up to 9 g/L fbr U and Pu. Two calculation methods, calibration curve method and standard addition method, were studied to measure Pu concentration in organic solution. Detection limit was 5.3 mg/L and 0.2 mg/L, respectively.
Naito, Osamu; Yoshida, Hidetoshi; Kitamura, Shigeru; *; *
Review of Scientific Instruments, 70(9), p.3780 - 3781, 1999/09
Times Cited Count:17 Percentile:71.61(Instruments & Instrumentation)no abstracts in English
Sasamoto, Hiroshi; Yui, Mikazu; Savage, D.*; Bille, B.*
JNC TN8400 99-025, 32 Pages, 1999/06
Groundwater data used for modelling site or repository evolution need to be assessed for their quality and whether they are "fit for purpose", prior to utilization. This report discuss factors and issues which impinge upon the quality of such data. It is recommended that geochemical modelleres : (1)are aware of how groundwater samples were collected, whether during drilling, during hydraulic testing, or thereafter, by in-situ measurement, pumped from boreholes, or by pressurised sampler ; (2)are aware of what procedures (if any) were used to "correct" samples for drill fluid contamination and what errors were associated with those methods ; (3)are aware of whether samples were subject to de-pressurisation during sampling, and whether geochemical modelling techniques were applied to correct the compositions of samples for that process ; (4)request different measures of redox activity (e.g., electrode measurements of Eh, concentrations of different redox-sensitive aqueous species) to be applied to key groundwater samples to investigate the extent of redox equilibrium ; (5)are aware of how groundwater samples were filtered and preserved for off-site analysis ; (6)ensure that adequate methods of groundwater filtration ( 0.1m) and chemical analysis are applied to ensure accurate and reproducible analyses for dissolved aluminum at low levels of concentration (generally less than 0.2 mg/L) ; (7)are aware of elemental errors and detection limits in chemical analysis of groundwater samples and assess the quality of groundwater analyses via ion exchange balances and via a comparison of measured and calculated values for total dissolved solids contents. (8)ensure that detailed mineralogical analysis is carried out on rock samples from locations where key groundwater samples have been extracted.
Fujisaku, Kazuhiko*; Ishibashi, Yuzo; Takeda, Seiichiro; ; *
PNC TN8410 98-115, 50 Pages, 1998/09
None
Hazama, Taira
PNC TN9410 98-073, 48 Pages, 1998/08
The theoretical formula for the statistical error estimation in Mihalczo method was derived, and the dependence of the error were investigated on the facility to be measured and on the parameter in the data analysis. The formula was derived based on the reactor noise theory and the error theory for the frequency analysis, and found that the error depends on such parameters as the prompt neutron decay constant, detector efficiencies, and the frequency bandwidth. Statistical errors estimated with the formula was compared with experimental values and verified to be reasonable. Through parameter surveys, it is found that there is a setting in the data analysis to optimize the magnitude and reliability of the errors. In the experiment performed in DCA subcriticality measurement facility, it is estimated experimentally that the measurement requires 20 minutes to obtain the statistic error of 1% for the keff 0.9. According to the error theory, this should be reduced to 3sec in the aqueous fuel system typical in fuel reprocessing plant.
; *; Ikeda, Hisashi ; Kaminaga, Kazuhiro; ; ; Kuno, Yusuke
PNC TN8410 96-266, 67 Pages, 1996/05
None
*; Asano, Tomohiro; *; Shinohara, Kunihiko*; *; Miura, Makoto
PNC TN841 83-08, 69 Pages, 1983/02
no abstracts in English